DR# 28536
Author: Jordan Josh
Equipment: Sheeter 4
Area: Cartridge Loader
Issue Date/Time:
2025-09-10 10:01:00
Problem Text:
some lids not openening
Followup Comments:
Assignee: Crist, David
Corrective Action Date:
2025-09-10 18:51:00
Corrective Action:
adjusted wrap up from 40 to 30psi, squared transfer table to wrap up roller, repositioned sensor (far east sensor near motor) for wrap up transer to 3/32nd of inch to east to accomodate new postion of transfer table, made new witness marks for new location. watched periodaclly with mirrow to see correct engagement of wrap up roller and cartridges without issues for the better half the day.